Chapter 18.05
AMENDMENTS TO CHAPTER 17, STRUCTURAL TESTS AND SPECIAL INSPECTIONS, OF THE CALIFORNIA BUILDING CODE

Sections:

18.05.005    Chapter 17 Is Amended.

18.05.010    Section 1705.3 Is Amended.

18.05.005 Chapter 17 Is Amended.

The following sections of Chapter 17 of the California Building Code, as adopted by Chapter 18.01 hereof, are added, deleted, or amended as follows. (Ord. 22-10 § 2, 12/13/22)

18.05.010 Section 1705.3 Is Amended.

Section 1705.3 is amended to read as follows:

1705.3 Concrete Construction. The special inspections and verifications for concrete construction shall be as required by this section and Table 1705.3.

Exceptions: Special inspection shall not be required for:

1.    Isolated spread concrete footings of buildings three stories or less above grade plane that are fully supported on earth or rock, where the structural design of the footing is based on a specified compressive strength, f’c, no greater than 2,500 pounds per square inch (psi) (17.2 MPa).

2.    Continuous concrete footings supporting walls of buildings three stories or less in height that are fully supported on earth or rock where:

2.1.    The footings support walls of light-frame construction;

2.2.    The footings are designed in accordance with Table 1809.7; or

2.3.    The structural design of the footing is based on a specified compressive strength, f’c, no greater than 2,500 pounds per square inch (psi) (17.2 MPa), regardless of the compressive strength specified in the construction documents or used in the footing construction.

3.    Nonstructural concrete slabs supported directly on the ground, including prestressed slabs on grade, where the effective prestress in the concrete is less than 150 psi (1.03 MPa).

4.    Concrete patios, driveways and sidewalks, on grade.

(Ord. 22-10 § 2, 12/13/22)