17.32.010 Water supply.
The water supply shall come from the city water system and shall be provided to all plumbing fixtures in mobile home parks and to individual water connections provided at each mobile home lot. (Prior code § 17.32.010)
17.32.020 Water connections.
A. Water connections for individual mobile homes shall be provided and located on the same side of the lot as the sewer lateral and shall consist of a riser terminating at least twelve inches above the ground surface with two three-quarter inch valved outlets threaded for screw-on connections. Such water connection shall be equipped with a shut-off valve placed below frost depth, (but in no case shall this valve be a stop and waste cock) shall be protected from freezing and from damage from mobile home wheels and shall have the ground surface around the riser pipe graded to divert surface drainage away from the connection.
B. Water piping may be installed in the same trench as tight joint sewer pipe provided the water pipe is laid on a shelf not less than twenty-four inches above the sewer pipe. (Prior code § 17.32.020)
17.32.030 Sewage, waste water drainage.
All sewage and waste water from toilets, urinals, slop sinks, bathtubs, showers, lavatories, laundries, and all other sanitary fixtures in a mobile home park, shall be drained to a public sewage collection system. (Prior code § 17.32.030)
17.32.040 Water main approval required.
Water distribution mains within the confines of the mobile home park shall be approved by the water department in relation to the materials, sizing, and design of the system. (Prior code § 17.32.040)
17.32.050 Plumbing compliance with code required.
All plumbing in the mobile home park shall comply with the city plumbing code. (Prior code § 17.32.050)
17.32.060 Sewer connections.
Each mobile home space shall be provided with at least four inch sewer connection. The sewer connection shall be provided with suitable fittings so that a watertight connection can be made between the mobile home drain and the sewer connection. Such individual home connections shall be so constructed that they can be closed when not linked to a home, and shall be trapped in such a manner as to maintain them in an odor free condition. Adapters, allowing for a tight, physical connection, shall be on the mobile home, or provided by the mobile home park operator for the use of mobile homes. (Prior code § 17.32.060)
17.32.070 Sewer line construction.
Sewer lines shall be constructed in accordance with the recommendations of the city engineer. (Prior code § 17.32.070)