4-2-130A

DEVELOPMENT STANDARDS FOR INDUSTRIAL ZONING DESIGNATIONS  

 

IL

IM

IH

LOT DIMENSIONS

Minimum Lot Size for lots created after September 1, 1985

35,000 sq. ft.

Minimum Lot Width/Depth for lots created after September 1, 1985

None

LOT COVERAGE

Maximum Lot Coverage for Buildings

65% of total lot area or 75% if parking is provided within the building or within a parking garage

None

HEIGHT

Maximum Building Height5, except for Public Facilities5,13

50 ft.;
Heights may exceed maximum with a Conditional Use Permit.

Maximum Height for Wireless Communication Facilities5

See RMC 4-4-140.

SETBACKS8,11

Minimum Front Yard

Principal Arterial streets:12 20 ft.

Other streets: 15 ft.; provided, that 20 ft. is required if a lot is adjacent to or abutting a lot zoned residential.

Principal Arterial streets:12 20 ft.

Other streets: 15 ft. Except 50 ft. is required if a lot is adjacent to or abutting a lot zoned residential.

Principal Arterial streets:12 20 ft.

Other streets: 15 ft.

Minimum Secondary Front Yard

Principal Arterial streets:12 20 ft.

Other streets: 15 ft. Except 50 ft. is required if a lot is adjacent to or abutting a lot zoned residential.

Principal Arterial streets:12 20 ft.

Other streets: 15 ft.

Minimum Freeway Frontage Setback

10 ft. landscaped setback from the property line.

Minimum Rear and Side Yards11

None, except 20 ft. if lot is adjacent to or abutting a lot zoned residential; which may be reduced to 15 ft. through the Site Plan development review process.

None, except 50 ft. if lot is adjacent to or abutting a lot zoned residential.

None, except 50 ft. if lot abuts a lot zoned residential.

20 ft. if lot abuts a lot zoned CN, CV, CA, CD, CO, COR, or lot with Public Facilities.

Clear Vision Area

In no case shall a structure over 42 in. in height intrude into the 20 ft. clear vision area defined in RMC 4-11-030.

LANDSCAPING

General

See RMC 4-4-070

SCREENING

Minimum Required for Outdoor Loading, Repair, Maintenance or Work Areas; Outdoor Storage, Refuse or Dumpster Areas

See RMC 4-4-095

Special Screening Requirements for Tow Truck Operations and Impoundment Yards

NA

6 to 10 ft. high solid wall or sight-obscuring fence required.

LOADING DOCKS

Location

Not permitted on the side of the lot that is adjacent to or abutting a lot zoned residential.2

NA

DUMPSTER/RECYCLING COLLECTION STATION OR CENTER

Location of Refuse or Recycling Areas

See RMC 4-4-090

PARKING

General

See RMC 4-4-080 and 10-10-13

SIGNS

General

See RMC 4-4-100

CRITICAL AREAS

General

See RMC 4-3-050 and 4-3-090

(Ord. 4851, 8-7-2000; Amd. Ord. 4963, 5-13-2002; Ord. 5153, 9-26-2005; Ord. 5528, 3-8-2010; Ord. 5574, 11-15-2010; Ord. 5676, 12-3-2012; Ord. 5744, 1-12-2015; Ord. 5746, 1-12-2015; Ord. 5759, 6-22-2015; Ord. 5841, 6-12-2017; Ord. 5965, 3-2-2020; Ord. 6100 (Att. B), 12-5-2022)