Chapter 13.10
UTILITIES – DESIGN
Sections:
13.10.010 Utilities.
(a) All water and wastewater facilities shall be designed and constructed in accordance with Chapters 13.20 and 13.35 WMC.
(b) Street Lighting (Responsibility of the Town). The following table shows the minimum street lighting standards in the town. The values listed shall be increased by 40 percent at installation to account for illumination depreciation from age, dirtiness and luminaire loss.
Minimum lighting standards, foot-candles (divide by 0.6 at time of installation) are as follows:
Type of roadway |
Land use district |
||
---|---|---|---|
|
R, RH, PUD |
MHP, MHS |
HB, GUB, LID, HID |
Collector |
0.6 |
|
1.2 |
Local |
0.4 |
0.3 |
0.9 |
Pedestrian Walkways |
0.2 |
0.1 |
0.9 |
Light bulbs shall have a minimum 400-watt rating, 20,500-lumen rating, and 24,000-hour expectancy. [Ord. 419 Ch. 6 § 2, 1976. 1996 Code § 7-106.]