CHAPTER 4-10
2018 INTERNATIONAL SWIMMING POOL AND SPA CODE
Sections:
4-10-001-0001 AMENDMENTS, ADDITIONS, AND DELETIONS
4-10-001-0001 AMENDMENTS, ADDITIONS, AND DELETIONS
The following provisions shall have the effect of either amending, adding to, or deleting from the 2018 International Swimming Pool and Spa Code (ISPSC) adopted in Flagstaff City Code, Title 4, Building Regulations, Chapter 4-01, Administrative Enactments, Section 4-01-001-0002, Adoption of Model Codes.
CHAPTER 1, SCOPE AND ADMINISTRATION
Section 108, Means of Appeal
Amend 2018 ISPSC 108.1, Application for appeal, by deleting and replacing with:
In order to hear and decide appeals of orders, decisions or determinations made by the Building Official relative to the application and interpretation of this code, there shall be and is hereby created a Building and Fire Code Board of Appeals per Flagstaff City Code, Title 2, Boards and Commissions.
Amend 2018 ISPSC Sections 108.2 through 108.7, by deleting in their entirety.
CHAPTER 2, DEFINITIONS
Section 202, Definitions
Amend 2018 ISPSC Section 202, Definitions, by adding:
RESIDENTIAL SWIMMING POOL (RESIDENTIAL POOL). A pool intended for use that is accessory to a residential setting and available only to the household and its guests including any structure intended for swimming or recreational bathing that contains water over eighteen (18) inches in depth. This includes in-ground, above ground, and on-ground swimming pools, hot tubs, spas, and fixed in place wading pools. Other pools shall be considered to be public pools for purposes of this code.
CHAPTER 3, GENERAL COMPLIANCE
Section 305, Barrier Requirements
Amend 2018 ISPSC 305.2.1, Barrier height and clearances, by revising as follows:
1. The top of the barrier shall be not less than sixty (60) inches above grade where measured on the side of the barrier that faces away from the pool or spa. Such height shall exist around the entire perimeter of the barrier and for a distance of three (3) feet measured horizontally from the outside of the required barrier.