Chapter 17.60
SERVICE BUILDINGS
Sections:
17.60.050 Toilet room screen, door requirements.
17.60.060 Lighting, window requirements for toilet, shower, laundry rooms.
17.60.070 Minimum temperature.
17.60.080 Hot water requirements.
17.60.090 Toilet, lavatory and shower facilities.
17.60.100 Walkway width, surfacing.
17.60.110 Clothes drying facilities.
17.60.120 Surfaced, lighted walkways required.
17.60.010 Generally.
Service buildings are optional. If, however, a service building is constructed it shall meet the conditions designated in Sections 17.60.020 through 17.60.130. (Prior code § 17.60.010)
17.60.020 Location.
Service buildings shall be located not less than twenty feet from any mobile home lot. (Prior code § 17.60.020)
17.60.030 Construction.
Service buildings shall be of permanent construction with an interior finish of light colored moisture-resistant material which will stand frequent washing and cleaning. (Prior code § 17.60.030)
17.60.040 Floors.
The floors shall be of water-impervious material, easily cleanable, and sloped to floor drains connected to the sewage system. The service building shall be maintained in a clean condition at all times. (Prior code § 17.60.040)
17.60.050 Toilet room screen, door requirements.
The buildings shall be well ventilated; all exterior openings from toilet rooms shall be covered with sixteen mesh screen. Toilet rooms shall be provided with self-closing doors. (Prior code § 17.60.050)
17.60.060 Lighting, window requirements for toilet, shower, laundry rooms.
Toilet, shower and laundry rooms shall be well lighted at all times. Window area shall be provided equivalent to at least twelve percent of the floor area. (Prior code § 17.60.060)
17.60.070 Minimum temperature.
During periods of use, service buildings shall be maintained at a seventy degrees Fahrenheit minimum. (Prior code § 17.60.070)
17.60.080 Hot water requirements.
Hot water shall be provided for lavatory, bathing and laundry room fixtures, with facilities of sufficient capacity to supply three gallons per hour per dependent mobile home space. (Prior code § 17.60.080)
17.60.090 Toilet, lavatory and shower facilities.
Service buildings shall have toilet, shower and lavatory facilities separate for the sexes, with a minimum of two toilets for females, one toilet for males, one urinal for males, two lavatories and one shower for each sex. (Prior code § 17.60.090)
17.60.100 Walkway width, surfacing.
Walkways to and from every service building shall be provided at least two feet six inches in width and bituminous surfaced or better. Driveways may be considered as walkways. (Prior code § 17.60.100)
17.60.110 Clothes drying facilities.
Adequate clothes drying facilities adjacent to, or in, the service building shall be provided. (Prior code § 17.60.110)
17.60.120 Surfaced, lighted walkways required.
Surfaced and lighted walkways shall be provided to all service buildings. (Prior code § 17.60.120)
17.60.130 Laundry facilities.
Laundry facilities, together with laundry drying facilities, shall be provided. No less than one double laundry tray or automatic washing machine shall be provided for each twenty mobile home lots in the mobile home park. Laundry facilities shall be in a room or rooms separate from the toilet facilities and such room shall have an exterior door. (Prior code § 17.60.130)