Chapter 21.10
INTERNATIONAL RESIDENTIAL CODE
Sections:
21.10.010 International Residential Code adopted.
21.10.013 Copies on file.
21.10.016 Administration.
21.10.020 IRC Table R301.2 amended.
21.10.025 Repealed.
21.10.010 International Residential Code adopted.
The 2021 Edition of the International Residential Code, as adopted by the State Building Code Council in Chapter 51-51 WAC, as published by the International Code Council, excluding Chapter 1, “Administration,” is adopted, together with the following amendments. The Construction Administrative Code, as set forth in Chapter 21.06, shall be used in place of IRC Chapter 1, Administration. (Ord. 4848 § 30, 2024; Ord. 4751 § 27, 2021; Ord. 4524 § 46, 2016: Ord. 4410 § 7, 2013: Ord. 4246 § 3 (part), 2010: Ord. 4099 § 4 (part), 2007: Ord. 3946 § 1 (part), 2004)
21.10.013 Copies on file.
The city shall at all times keep on file with the city clerk, for reference by the general public, not less than one copy of the International Residential Code. (Ord. 4246 § 3 (part), 2010: Ord. 4208 § 4 (part), 2009)
21.10.016 Administration.
The administrative provisions for the enforcement of the International Residential Code are located in Chapter 21.06. (Ord. 4246 § 3 (part), 2010: Ord. 4208 § 4 (part), 2009)
21.10.020 IRC Table R301.2 amended.
IRC Table R301.2 is amended to read:
ROOF SNOW LOADa (psf) |
WIND DESIGN |
SEISMIC DESIGN CATEGORY |
SUBJECT TO DAMAGE FROM |
OUTDOOR DESIGN TEMP (F) - Heat/ Cool |
ICE BARRIER UNDERLAYMENT REQUIRED |
FLOOD HAZARDe |
AIR FREEZING INDEX |
MEAN ANNUAL TEMP |
|||||
Speedb (mph) |
Topographic effectsc |
Special wind region |
Windborne debris zone |
Weatheringd |
Frost line depth |
Termite |
|||||||
25 |
98 |
Yes |
No |
No |
D2 |
Moderate |
12” |
Slight to Moderate |
83/17 |
No |
N.A. |
113 |
53oF |
MANUAL J DESIGN CRITERIA |
|||||||||||||
Elevation |
Altitude correction factor |
Coincident wet bulb |
Indoor winter design dry-bulb temperature |
Indoor winter design dry-bulb temperature |
Outdoor winter design dry-bulb temperature |
Heating temperature difference |
|||||||
338 feet |
0.99 |
66oF |
72oF |
72oF |
24oF |
48oF |
|||||||
Latitude |
Daily Range |
Indoor summer design relative humidity |
Summer design gains 50% RH |
Indoor summer design dry-bulb temperature |
Outdoor summer design dry-bulb temperature |
Cooling temperature difference |
|||||||
47o39’26’’ |
M |
50% |
5 |
75oF |
83oF |
8oF |
a. This is the minimum roof snow load. When using this snow load it will be left to the engineer’s judgment whether to consider drift or sliding snow. However, rain on snow surcharge of 5 psf must be considered for roof slopes less than 5 degrees.
b. The basic wind speed is determined from the basic wind speed map in Figure R301.2(2). Wind exposure category shall be determined on a site-specific basis in accordance with Section R301.2.1.4.
c. Topographic effects (Wind Speed-up Kzt factor) shall be determined on a site-specific basis in accordance with Section R301.2.1.5.
d. Weathering may require a higher strength concrete or grade of masonry than necessary to satisfy the structural requirements of this code. The grade of masonry units shall be determined from ASTM C34, C55, C62, C73, C90, C129, C145, C216 or C652.
(Ord. 4848 § 31, 2024; Ord. 4751 § 28, 2021; Ord. 4524 § 47, 2016: Ord. 4410 § 8, 2013: Ord. 4246 § 3 (part), 2010: Ord. 4099 § 4 (part), 2007)
21.10.025 IRC 311.7.7, Stairway walking surface, amended.
Repealed by Ord. 4848. (Ord. 4751 § 29, 2021)