Chapter 18.60
LOT AND STRUCTURE
DIMENSIONAL REQUIREMENTS

Sections:

18.60.010    Generally.

18.60.020    Lot standards.

18.60.030    Dimensional requirements.

18.60.010 Generally.

This chapter sets out the dimensional requirements for lots and structures located within the zoning districts described in Chapters 18.16 through 18.52 OMC. (Ord. 660 § 18.00, 1985)

18.60.020 Lot standards.

The following chart and text of this section describe the dimensional requirements for lots located within the zoning districts described in Chapters 18.15 through 18.52 OMC:

Chart 1

Dimensional Requirements

 

 

 

Minimum Setbacks

District

Min. Sq. Ft.

Min. Width

Front

Rear

Side

Street

R-R

20,000

100′

40′

40′

10′

25′

R-1

8,000

75′

20′

20′

5′

20′

R-2

5,000

50′

20′

20′

5′

20′

R-2D

Single-family

Duplex

 

5,000

7,500

 

50′

75′

 

20′

20′

 

20′

20′

 

5′

5′

 

20′

20′

R-3

5,000

50′

20′

20′

5′

20′

R-4

none

50′

20′

20′

5′

20′

C-1

none

none

see Exception 4

C-19

5,000

50′

20′

20′

5′

20′

C-2

5,000

50′

see Exceptions 4 and 5

C-29

5,000

50′

20′

20′

5′

20′

C-3

5,000

50′

see Exceptions 4 and 5

C-39

5,000

50′

20′

20′

5′

20′

I-1

5,000*

50′

see Exceptions 4 and 5

I-2

5,000*

50′

see Exceptions 4 and 5

Conservancy

see Exception 7

*Smaller lot sizes can be achieved if done by PUD.

Exceptions:

1. Front Yards. If there are dwellings on both abutting or adjoining lots with front yards of less than the required depths for the underlying zoning district, the front yard for the lot need not exceed the average front yard depth of the abutting dwellings.

2. If there is a dwelling on one abutting or adjoining lot with a front yard or less than the required depth for the underlying zoning district, the front yard depth for the lot need not exceed the average between the front yard depth with less than the required depth and the required front yard depth for the underlying zoning district.

3. To permit or afford better light, air and vision on more heavily traveled streets and on streets of substandard width, to protect arterial streets and to permit the eventual widening of streets, the distance of any structure from the street right-of-way and from the centerline of the street shall be as follows: In a residential district, 20 feet from the edge of the property line or, where deeded right-of-way exists, the setback shall be 50 feet from the centerline, whichever is greater.

4. When commercial or industrial districts abut residential districts, side yards shall be at least five feet and rear yards shall be at least 10 feet.

5. In commercial and industrial districts front yard setback requirements will be as follows: Fifty feet from centerline where deeded right-of-way exists, or 20 feet from the property line, whichever is greater.

6. In residential districts, the yard requirements shall be increased by one foot for each foot by which the building height exceeds 25 feet.

7. In the conservancy district, residential uses shall follow the requirements for the R-1 district. All other uses shall be subject to the requirements of commercial or industrial districts.

8. On corner lots the setback on the street side of the lot shall be a minimum of 10 feet.

9. Requirements apply to residential uses only. (Ord. 873 § 1, 1999; Ord. 805 § 2, 1995; Ord. 737 § 3, 1990; Ord. 660 § 18.01, 1985)

18.60.030 Dimensional requirements.

The following chart and text of this section describe the dimensional requirements for structures located within the zoning districts described in Chapters 18.15 through 18.52 OMC:

Chart 2

Height, Bulk and Density Requirements

District

Max. Height

Min. Floor Area

Max. Density*

Max. Lot Coverage

R-R

35′

1200 sq. ft.

2.8 DU/acre

20%

R-1

35′

700 sq. ft.

6.5 DU/acre

35%

R-2

35′

700 sq. ft.

10.4 DU/acre

35%

R-3

35′

700 sq. ft.

10.4 DU/acre

35%

R-4

35′

700 sq. ft.

18.0 DU/acre

40%

C-1

50′

none

none

none

C-15

50′

700 sq. ft.

18.0 DU/acre

80%

C-2

50′

none

none

none

C-25

50′

700 sq. ft.

9-18 DU/acre

40%

C-3

50′

none

none

none

C-35

50′

700 sq. ft.

9-18 DU/acre

40%

I-1

none

none

none

none

I-2

none

none

none

none

Conservancy

see Exception 4

*Maximum densities may be reached only by PUD (planned unit development).

Exceptions:

1. The following types of structural parts are subject to conditional use permit and building height limitations of this title: aerials, belfries, chimneys, church spires, elevator shafts, fire and hose towers, flagpoles, monuments, television and radio towers, smokestacks, transmission towers, water towers, windmills and other similar projections.

2. Projections from buildings including cornices, eaves, gutters, sunshades and other similar architectural features may not project more than two feet into required yard areas.

3. When multifamily dwellings are to be built, the minimum lot size shall be increased by not less than 200 square feet for each unit.

4. Residential dwellings in the conservancy district shall follow the requirements for the R-1 district. All other uses shall be subject to the requirements for the industrial and commercial districts.

5. Requirements apply to residential uses only.

6. Maximum density may only be reached when full city services (i.e., water and sewer) are available. (Ord. 805 § 3, 1994; Ord. 737 § 4, 1990; Ord. 660 § 18.02, 1985)